variants: Heltec Mesh Solar: Use DC/DC regulator

The schematic shows the LC circuit for the internal DC/DC regulator
to be available. Enable it to save power.

Signed-off-by: Frieder Schrempf <frieder@fris.de>
This commit is contained in:
Frieder Schrempf 2025-12-19 11:35:27 +01:00
parent 578d55b28a
commit 24a4b99e31
No known key found for this signature in database
GPG key ID: E7DD51F45F833802

View file

@ -20,7 +20,7 @@
#define SX126X_DIO2_AS_RF_SWITCH true
#define SX126X_DIO3_TCXO_VOLTAGE 1.8
class MeshSolarBoard : public NRF52BoardOTA {
class MeshSolarBoard : public NRF52BoardDCDC, public NRF52BoardOTA {
public:
MeshSolarBoard() : NRF52BoardOTA("MESH_SOLAR_OTA") {}
void begin();