import unittest
from tests.libreVNA import libreVNA as libreVNA
import tests.definitions as defs
import subprocess
import time
import select
from signal import SIGINT
class TestBase(unittest.TestCase):
def setUp(self):
self.gui = subprocess.Popen([defs.GUI_PATH, '-p', '19544', '--reset-preferences'], stdout=subprocess.PIPE, stderr=subprocess.STDOUT)
# wait for the SCPI server to become available
timeout = time.time() + 3;
poll_obj = select.poll()
poll_obj.register(self.gui.stdout, select.POLLIN)
while time.time() < timeout:
poll_result = poll_obj.poll(0)
if poll_result:
line = self.gui.stdout.readline().decode().strip()
if "Listening on port 19544" in line:
break
time.sleep(0.2)
self.vna = libreVNA('localhost', 19544)
try:
self.vna.cmd("*CLS;:DEV:CONN")
except Exception as e:
self.tearDown()
raise e
if self.vna.query(":DEV:CONN?") == "Not connected":
self.tearDown()
raise AssertionError("Not connected")
def tearDown(self):
self.gui.send_signal(SIGINT)
try:
self.gui.wait(timeout = 0.1)
except subprocess.TimeoutExpired:
self.gui.kill()