LibreVNA manual - to to into

This commit is contained in:
Bryan Paradis 2025-02-25 16:15:53 -08:00
parent 333f62bf0e
commit f7f5ebca47

View file

@ -1394,7 +1394,7 @@ Open the marker's context menu, choose "Add to linked group" and select the link
\end{itemize}
\section{Compound Device}
The LibreVNA supports combining multiple hardware units to a "Compound Device". When used, the configured physical LibreVNAs are combined into a virtual device with more ports. When connected to such a device, additional measurement paramaters are available (e.g. measuring S23 in VNA mode or port 3 in spectrumanalyzer mode).
The LibreVNA supports combining multiple hardware units into a "Compound Device". When used, the configured physical LibreVNAs are combined into a virtual device with more ports. When connected to such a device, additional measurement paramaters are available (e.g. measuring S23 in VNA mode or port 3 in spectrumanalyzer mode).
\begin{important}
When connected to a compound device and in VNA mode, there is no phase information for through measurements between different physical devices. This is a hardware limitation and the phase is set to zero in the software. Through measurements within a physical device and all reflection measurements retain their phase information.