mirror of
https://github.com/jankae/LibreVNA.git
synced 2026-04-05 06:25:16 +00:00
Added single sweep functionality
This commit is contained in:
parent
53dcff8745
commit
d84d3e80aa
8 changed files with 124 additions and 11 deletions
Binary file not shown.
|
|
@ -382,6 +382,16 @@ Example (assuming <averaging sweep> = 3):
|
|||
\subsubsection{VNA:ACQuisition:LIMit}
|
||||
\query{Queries the status of limits that maybe set up on any graph}{VNA:ACQuisition:LIMit?}{None}{PASS or FAIL}
|
||||
|
||||
\subsubsection{VNA:ACQuisition:SINGLE}
|
||||
\event{Configures the VNA for single or continuous sweep}{VNA:ACQuisition:SINGLE}{TRUE or FALSE}
|
||||
\query{Queries whether the VNA is set up for single sweep}{VNA:ACQuisition:SINGLE?}{None}{TRUE or FALSE}
|
||||
|
||||
If single sweep is enabled, the acquisition is stopped when the required number of averages have been reached. There are two ways to trigger a new sweep:
|
||||
\begin{itemize}
|
||||
\item Change any sweep setting (e.g. center frequency)
|
||||
\item Issue the command again (i.e. VNA:ACQ:SINGLE TRUE always triggers a new sweep)
|
||||
\end{itemize}
|
||||
|
||||
\subsubsection{VNA:STIMulus:LVL}
|
||||
\event{Sets the output power of the stimulus signal when sweep type is frequency}{VNA:STIMulus:LVL}{<power>, in dBm}
|
||||
\query{Queries the currently selected output power}{VNA:STIMulus:LVL?}{None}{power in dBm}
|
||||
|
|
@ -608,6 +618,16 @@ Example (assuming <averaging sweep> = 3):
|
|||
\subsubsection{SA:ACQuisition:LIMit}
|
||||
\query{Queries the status of limits that maybe set up on any graph}{SA:ACQuisition:LIMit?}{None}{PASS or FAIL}
|
||||
|
||||
\subsubsection{SA:ACQuisition:SINGLE}
|
||||
\event{Configures the spectrum analyzer for single or continuous sweep}{SA:ACQuisition:SINGLE}{TRUE or FALSE}
|
||||
\query{Queries whether the spectrum analyzer is set up for single sweep}{SA:ACQuisition:SINGLE?}{None}{TRUE or FALSE}
|
||||
|
||||
If single sweep is enabled, the acquisition is stopped when the required number of averages have been reached. There are two ways to trigger a new sweep:
|
||||
\begin{itemize}
|
||||
\item Change any sweep setting (e.g. center frequency)
|
||||
\item Issue the command again (i.e. SA:ACQ:SINGLE TRUE always triggers a new sweep)
|
||||
\end{itemize}
|
||||
|
||||
\subsubsection{SA:ACQuisition:SIGid}
|
||||
\event{Enables/disables signal identification}{SA:ACQuisition:SIGid}{<enabled>, option are TRUE, FALSE, 1 or 0}
|
||||
\query{Queries whether signal identification is enabled}{SA:ACQuisition:SIGid?}{None}{TRUE or FALSE}
|
||||
|
|
|
|||
Loading…
Add table
Add a link
Reference in a new issue